Abstract
The coulometric-weighing test method was established and applied to determine the tin coating mass for electrolytic timplate. The effects of electric quantity, the current efficiency and the electrochemical equivalent in the coulometric test method were overcome. the inaccuracy in the determination of final point at the anodic dissolution curve in the weighing method was avoided when applied to the electrolytic timplate, higher accuracy was obtained, the SD is less than 0.04 g/m~2,RSD is as small as 0.36%.
Keywords
Coulometric-weighting test method, Coating mass determination, Electrolytic tinplate
Publication Date
2004-02-28
Online Available Date
2004-02-28
Revised Date
2004-02-28
Received Date
2004-02-28
Recommended Citation
Xiu-wen DONG.
Coulometric-Weighing Test Method and Its Application in Determination of Tin Coating Mass for Electrolytic Tinplate[J]. Journal of Electrochemistry,
2004
,
10(1): 102-106.
DOI: 10.61558/2993-074X.1553
Available at:
https://jelectrochem.xmu.edu.cn/journal/vol10/iss1/17
References
[1] SongZhi_di.CoatingThicknessMeasurementTechnology[M].Beijing:PressofWaterResourcesandElectricPower,1992.
[2] LiGuo_ying.SurfaceEngineeringHandbook[M].Beijing:ChinaMachinePress,2001.
[3] DongXiu_wen,LinGuo_wei,LiuJian_guo,etal.Intelligenttinplatecoatingmassanalyzer[P].China:ZL01272056.9,2002_11_20.
[4] JISG3303_1987,TinplateandBlackplate[S].
[5] ASTMA630_1998,StandardTestMethodsforDeterminationofTinCoatingWeightsforElectrolyticTinPlate[S].
[6] SongMing_sun.UncertaintyinMeasurementandItsPractice[M].Beijing:ChinaMetrologicalPress,2000.