•  
  •  
 

Corresponding Author

Jian-bin ZHENG

Abstract

In 0.2 mol L~(-1) NaOH solution, ethamsylate can yield a sensitive incision on cathodic branch of dE/dt-E osillogram at 0.3V (vs. SCE). Based on the oscillographic characteristic, a second order differential simple oscillographic voltammetry for determination of ethamsylate in tablet and injection is presented in this paper. The peak height on second order differential simple oscillographic voltammogram is linearly proportional to concentration of the ethamsylate in the range of 1.5×10~(-5)~3.4×10~(-4) mol·L~(-1 )with a 0.9921 correlation coefficient and a detection limit of 6.0×10~(-6 )mol·L~(-1 ) for ethamsylate. The relative standard deviation is 2.1% for the determination of 3.0 10~(-5) mol L~(-1) ethamsylate (n=5). Compared with HPLC and other methods, the second order differential simple oscillographic voltammetry is a convenient method due to its cheap equipment and rapid measurement.

Keywords

Oscillographic analysis, Oscillographic determination, Drug analysis, Ethamsylate

Publication Date

2005-05-28

Online Available Date

2005-05-28

Revised Date

2005-05-28

Received Date

2005-05-28

References

[1]Editorialcommitteeofpharmacopeiaoftheministryof healthofChina(中华人民共和国卫生部药典委员会).PharmacopeiaofChina:PartⅡ[M].Beijing:ChemicalIndustryPress,1995.788.
[2]XuZC(许自超),LiXH(李晓晔),ShiJ(施炯),et al.Thespectrometricdeterminationofethamsylateinstomachtissueofrabbit[J].ChineseJournalofAna lyticalChemistry,1994,22(4):420.
[3]MaJW(马剑文),LIUYB(刘玉波).HPLCanalysis ofethamsylate[J].ChinesejournalofPharm.Anal.,1984,4(4):209~212.
[4]YangGJ(杨功俊),JinLT(金通利),LengZZ(冷宗周).Determinationofmicroscaleethamsylateoncar bonpasteelectrodewithadsorptivevoltammetry[J].ChinesejournalofPharm.Anal.,1998,18(5):311~313.
[5]WangZH(汪振辉),ZhangD(张岱),ZhangY(张岩),etal.Voltammetricbehaviorofdicynonumatpoly(4aminopyridine)filmmodifiedelectrodeanditsdeter minationbyadsorptivestrippingvoltammetry[J].Chi neseJournalofAnalyticalChemistry,2001,29(1):83~86.
[6]HunX(混旭),YangWP(杨维平),ZhangZJ(章竹君).Anovelaerodynamicforcecapillarymicrodrop in jectiondeterminationofethamsylatewithchemilumines cence[J].ChemicalJournalofChineseUniversities,2004,25(2):264~266.
[7]LiYH(李银环),DuJX(杜建修),LvJR(吕九如).Chemiluminescencereactionofluminal[potassi umferricyanide potassiumferrocyanide]ethamsylate system[J].ChineseJournalofAnalyticalChemistry,2002,30(6):742~744.
[8]YangFZ,ZhangC,WillyRGB,etal.Determination ofethamsylateinpharmaceuticalpreparationsbasedon anauto oxidationchemiluminescencereaction[J].J.PharmaceuticalandBiomedicalAnalysis,2002,30:473~478.
[9]ZhengJB,ZhangXQ,GaoM,etal.Astudyona Multi orderSemidifferentialOscillographicChronopoten tiometricInstrument[J].InstrumentationScience&Technology,2000,28(5):403~412.
[10]ZhengJB(郑建斌),GaoH(高鸿).Theadjustingof oscillograminoscillographicdetermination[J].Jour nalofNorthwestUniversity(NaturalScienceEdition),1995,25(4):309~314.
[11]ZhengJB(郑建斌),FuYW(高鸿),LiY(李媛),etal.Investigationof3.5thorderdifferentialcyclicos cillochronopotentiometry[J].ChemicalJournalof ChineseUniversities,1998,19(3):368~371.
[12]GaoH(高鸿).OscillographicMedicalAnalysis[M].Chengdu:SichuanEducationPress.1992,263.

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.