Abstract
The existence of electrochemical reaction during the corrosion process of pure Fe under a deposit of solid NaCl in water vapor at above 400 ℃ had been detected by measuring the corrosion current using double-layer electrode.In EIS measurement,only one capacitive loop was obtained on the pure metals and this gave the information of oxide layer on them.The electrochemical impedance spectroscopy(EIS) and scanning-electron microscopy(SEM) results testified that there is a good relationship between the resistance of oxide layer Rox and the corresion reaction rate for pure metals with different oxidation times.The electrochemical technique is an effective method for studying corrosion performance at high temperature.
Keywords
water vapor, synergistic effect, EIS, oxidation
Publication Date
2009-05-28
Online Available Date
2009-05-28
Revised Date
2009-05-28
Received Date
2009-05-28
Recommended Citation
Li LIU, Ying LI, Fu-hui WANG.
The Mechanism of Electrochemical Testing Method under Synergistic Effect of NaCl and Water Vapor at 600℃[J]. Journal of Electrochemistry,
2009
,
15(2): 179-183.
DOI: 10.61558/2993-074X.1975
Available at:
https://jelectrochem.xmu.edu.cn/journal/vol15/iss2/10