Abstract
The microband array electrode(MAE) consisting of 11 Pt microband of 5 m in wide, 2000 m long and 85 m gap was fabricated with a thin film techology .The MAE was characterized by means of cyclic voltammetry in a solution of K3Fe(CN)6 and H2O2. The results showed higher current density on MAE than on conventional Pt eletrode due to the strong edge effect of the former. A glucose microsensor was constructed with the substrate electrode of microband array. Microband array electrode was modified by Nafion followed by the immobilization of ferrocene onto Nafion layer as the electron transfer mediator,finally a glucose microsensor was constructed by using bovine serum albumin and glutaraldehyde to immobilize glucose oxidase onto the surface of Nafion_Fc modified microband array electrode. The upper detection limit of the microsensor was 8.0 mmol/L and the response time was less than 10s.No significant variation was observed within two weeks use in detection.
Keywords
Microband array electrode, Glucose microsensor, Glucose oxidase, Nafion, Ferrocene
Publication Date
1999-05-28
Online Available Date
1999-05-28
Revised Date
1999-05-28
Received Date
1999-05-28
Recommended Citation
Nengqin Jia, Chuijue Sun, Ling Gao, Zongrang Zhang.
Study on the Microband Array Electrode_based Glucose Microsensor[J]. Journal of Electrochemistry,
1999
,
5(2): Article 10.
DOI: 10.61558/2993-074X.3173
Available at:
https://jelectrochem.xmu.edu.cn/journal/vol5/iss2/10
References
1MannBuxbaumE,PitnerF,SchalkhammerT.Newmicrominaturizedglucosesensorusingcovalentimmobilizationtechniques.SensorsandActuators,B1,1990,518~5222ZhangZR,ZhangGX,ZhuJZ,HuJ.Thedevelopmentofthickandthinfilm_basedmicrobiosensors,inA.P.F.Turner,R.Renneberg,E.K.Wang(ed.)AdvancesinBiosensors,JAIPress,London,1999,4:273~2893UrbanG,JobstG,KohlFetal.Miniaturizadthin_filmbiosensorsusingcoventlyimmobilizedglucoseoxidase.Biosensor&Bioelectuonics,1991,6:555~5624蔡称心,鞠煜先,陈洪渊.纳米级微金电极上葡萄糖氧化酶的固定、性质及应用.化学学报,1995,53:281~2855YonHin,BFY,SethiRS,LoweCR.Multi_analytemicroelectronicbosensors.Sensors&Actuators,1990,B1:550~5546JianzhongZhu,JialiWu,ChengyunTianetal.MicroarayH2O2electrodeasbaseelementsofhigh_responseglucosesensors.Sensors&ActuatrosB,1994,20:17~227AokiK,HondaK,TokudaK,MatsuadaH.Voltammetryatmicrocylinderelectrodes.Part1.Linearsweepvoltammetry.J.Eletroanal.Chem.,1985,182:267~2798KovachPM,CaudilWL,PetersDGetal.Faradaicelectrochemistryatmicrocylinder,band,andtubularbandelectrode.J.Electronal.Chem.1985,185:285~2959HauknesJK,MurphyOJ,HitchensG.D.Enzymeelectrodesbasedonionomerfilmscoatedonelectrodes.J.Electroanal.Chem.,1993,357;261~27210BrownRS,LuongJHT.Aregenerablepseudo_reagentlesglucosebiosensorbasedonNafionpolymerand1,1’_dimethylferriciniummediator.Anal.Chim.Acta.,1995,310:419~42711HarisonDJ,TurnerRFB,BaltesHP.Characterizationofperfluorosulfonicacidpolymercoatedenzymeelectrodesandaminiaturizedintegratedpotentiostatforglucoseanalysisinwholeblood.Anal.Chem.,1988,60:2002~2007
Included in
Analytical Chemistry Commons, Engineering Science and Materials Commons, Materials Chemistry Commons, Materials Science and Engineering Commons, Physical Chemistry Commons