•  
  •  
 

Abstract

Reaction mechanism of enzyme immunoelectrode is studied by potentiostatic. Rotating disk electrode is used to determine the controlling step of bioelectrode. Under different potentials and different modifying conditions, kinetic parameters of bioelectrodes were measured on the base of electrochemical impendance spectra. At the same time, these parameters are compared and discussed.

Keywords

Enzyme immunoelectrode, Staphylococcal Enterotoxin, kinetic parameters

Publication Date

2000-05-28

Online Available Date

2000-05-28

Revised Date

2000-05-28

Received Date

2000-05-28

References

[1] ShiZG ,YuY ,YaoYM ,etal.TheeffectoftheStaphylococcalenterotoxinBonrabbit’sorganfunction[J].JofHygieneResearch ,1998,Suppl.(2 7) :187.

[2 ] CharlesE .Kientz,AlbertGHulst,EricRJ.Wils.DeterminationofstaphylococcalenterotoxinBbyon_line(micro)liquidchromatography_electrospraymassspectrometry[J].JournalofchromatographyA ,1997,75 7:5 1.

[3] IchiroTajima,OsamuAsami,EikoSugiura.Monitorofantibodiesinhumansalivausingapiezoelectricquartzcrystalbiosensor[J].AnalyticaChimicaActa,1998,36 5 :147.

[4 ] HaoYu ,HafizAhmed ,GaradoR .Vasta.Developmentofamagenticmicroplatechemifluorimmunoassayforrapiddetectionofbacteriaandtoxininblood[J].Analyticalbiochemistry,1998,2 6 1:1.

[5 ] FGarciaSanchez ,ANavasDiaz,AFGonzalezDiaz,SAEremin .Quantificationof 2 ,4,5_trichlorlphe nocyaceticacidbyfluorescenceenzyme_linkedimmunosorbentassaywithsecondaryantibody[J].AnalyticaChimicaActa ,1999,378:2 19.

[6 ] RandyMWadkinst,JoelPGolden ,LeoMPritsiolas,FrancesSLigler.Detectionofmultipletoxicagentsusingaplanararrayimmunosensor[J].Biosensors&Bioelectronics,1998,13(3- 4):40 7.

[7] YuH .Useofanimmunomagneticseparation_fluorescentimmunoassay(IMS -FIA)forrapidandhighthroughputanalysisofenvironmentalwatersamples[J].AnalyticaChimicaActa,1998,376 :77.

[8] DongSY ,LvMX .Spectroscopicanalysesofbioelectrodes[J].In :ExtentedAbstractsofInternationdEco materialsConference:PartB ,Xi’an :ChineseMaterialsresearchSocietyandJapanEcomaterialsForum ,1995 :PA - 5 36 .

[9] DongSY ,LvMX ,HuangZC .InsituFTIRreflectionspectroscopyofHCGenzymeimmunoelectrode[J].Chinesejournalofbiomedicalengineering ,1995 ,14(2 ) :10 7.

[10 ] RobinsonGA ,ColeVM ,ForrestGC .Homogeneouselectrode -basedbioelectrochemicalimmunoassayforhumanchorionicgonadotrophin[J].Biosensors,1987/ 88,3:147.

[11] TianBy.ResearchreportonenzymeimmunoelectrodeforSEC1:[Master’sDegreePaper][M ].Tianjin :ThechemicalengineeringcollegeofTianjinUniversity ,1999.

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.