Abstract
Reaction mechanism of enzyme immunoelectrode is studied by potentiostatic. Rotating disk electrode is used to determine the controlling step of bioelectrode. Under different potentials and different modifying conditions, kinetic parameters of bioelectrodes were measured on the base of electrochemical impendance spectra. At the same time, these parameters are compared and discussed.
Keywords
Enzyme immunoelectrode, Staphylococcal Enterotoxin, kinetic parameters
Publication Date
2000-05-28
Online Available Date
2000-05-28
Revised Date
2000-05-28
Received Date
2000-05-28
Recommended Citation
Sa-Ying DONG, Xin-miao LIU, Yuan-zhi WANG, Guang-zhang CHEN, Ming-xiang LV, Bo-yi TIAN.
Determination of Kinetic Parameters of Enzyme-immunoelectrode for SEC Assay[J]. Journal of Electrochemistry,
2000
,
6(2): 175-180.
DOI: 10.61558/2993-074X.1378
Available at:
https://jelectrochem.xmu.edu.cn/journal/vol6/iss2/5
References
[1] ShiZG ,YuY ,YaoYM ,etal.TheeffectoftheStaphylococcalenterotoxinBonrabbit’sorganfunction[J].JofHygieneResearch ,1998,Suppl.(2 7) :187.
[2 ] CharlesE .Kientz,AlbertGHulst,EricRJ.Wils.DeterminationofstaphylococcalenterotoxinBbyon_line(micro)liquidchromatography_electrospraymassspectrometry[J].JournalofchromatographyA ,1997,75 7:5 1.
[3] IchiroTajima,OsamuAsami,EikoSugiura.Monitorofantibodiesinhumansalivausingapiezoelectricquartzcrystalbiosensor[J].AnalyticaChimicaActa,1998,36 5 :147.
[4 ] HaoYu ,HafizAhmed ,GaradoR .Vasta.Developmentofamagenticmicroplatechemifluorimmunoassayforrapiddetectionofbacteriaandtoxininblood[J].Analyticalbiochemistry,1998,2 6 1:1.
[5 ] FGarciaSanchez ,ANavasDiaz,AFGonzalezDiaz,SAEremin .Quantificationof 2 ,4,5_trichlorlphe nocyaceticacidbyfluorescenceenzyme_linkedimmunosorbentassaywithsecondaryantibody[J].AnalyticaChimicaActa ,1999,378:2 19.
[6 ] RandyMWadkinst,JoelPGolden ,LeoMPritsiolas,FrancesSLigler.Detectionofmultipletoxicagentsusingaplanararrayimmunosensor[J].Biosensors&Bioelectronics,1998,13(3- 4):40 7.
[7] YuH .Useofanimmunomagneticseparation_fluorescentimmunoassay(IMS -FIA)forrapidandhighthroughputanalysisofenvironmentalwatersamples[J].AnalyticaChimicaActa,1998,376 :77.
[8] DongSY ,LvMX .Spectroscopicanalysesofbioelectrodes[J].In :ExtentedAbstractsofInternationdEco materialsConference:PartB ,Xi’an :ChineseMaterialsresearchSocietyandJapanEcomaterialsForum ,1995 :PA - 5 36 .
[9] DongSY ,LvMX ,HuangZC .InsituFTIRreflectionspectroscopyofHCGenzymeimmunoelectrode[J].Chinesejournalofbiomedicalengineering ,1995 ,14(2 ) :10 7.
[10 ] RobinsonGA ,ColeVM ,ForrestGC .Homogeneouselectrode -basedbioelectrochemicalimmunoassayforhumanchorionicgonadotrophin[J].Biosensors,1987/ 88,3:147.
[11] TianBy.ResearchreportonenzymeimmunoelectrodeforSEC1:[Master’sDegreePaper][M ].Tianjin :ThechemicalengineeringcollegeofTianjinUniversity ,1999.
Included in
Engineering Science and Materials Commons, Materials Chemistry Commons, Materials Science and Engineering Commons, Physical Chemistry Commons