Abstract

The chronocoulometry for flowing solution was devoloped and applied to the detemination of copper(Ⅱ) in the waste water of plating.The linear range of copper(Ⅱ) was 2~16mg/L,and the relative standard deviation was less than 0.1% ( n =8).The recovery was 98%~103% for copper(Ⅱ) in the waste water.Chronocoulometry for flowing solution overcomed noise disturbance resulting from capacity current and variety of property of electrode surface.This method was sensitive,accurate and well reproducible.

Keywords

Chronocoulometry for flowing solution, Copper, Determination

Publication Date

2002-02-28

Online Available Date

2002-02-28

Revised Date

2002-02-28

Received Date

2002-02-28

References

[1] GUOZhong_xian.Spectrophotometricdeterminationofmicroamountsofcopperbyflowinjectionanalysis[J].JournalofAnayticalScience(inchinese),1997,13(3):228(inchinese).

[2] LIUJia_qin,KUANGYun_yan,XUQi_heng.Newinhibition_kineticspectrophotometricdeterminationoftracecopper(Ⅱ)[J].ChineseJournalofAnalyticalChemistry,1998,26(10):1285(inchinese).

[3] SanAndresMP ,MarinaML .Spectrophotometricdeterminationofcopper(Ⅱ),nickel(Ⅱ)andcobalt(Ⅱ)ascomplexeswithsodiumdiethyldithiocarbamateincationicmicellarmidiumofhexadecyltrimethylammoniumsalts[J].Talanta,1994,41(2):179.

[4] WANGZhao_hong.AZeemangraphitefurnaceatomicabsorptionspectrometricmethodforthedeterminationoftracecopperandchromiumindrinkingwater[J].SpectrocopyandSpectralAnalysis(inchinese),1999,19(4):616~618(inchinese).

[5] JIANGChong_qiu,TANGBo,FUHong_yan,etal.Studyondeterminationofcopper(Ⅱ)withSalicylaldehydephenylhydrazonebyspectrophotofluorimetry[J].ChemicalJournalofChineseUniversities,1996,17(1):49(inchinese).

[6] ZHANGMing_hao,ZHOUChun_shan,LIZhi_hong,etal.Rapidandsimultaneousdeterminationoftracecop per,cadmiumandcobaltinzincelectrolytesoultionbyoscillopolarography[J].ChineseJournalofAnalyticalChemistry,2000,28(8):997(inchinese).

[7] HUZhe_song,ZHANGYi_ding.StudyonthepolarographicwaveofthecomplexbetweenCu(Ⅱ)and7_iodo_8_hydroxyquinoline_5_sulfonicacid[J].PhysicalTestingandChemicalAnalysis(PartB :ChemicalAnalysis),1993,29(6):360(inchinese).

[8] NationalEnvironmentalProtectionAgency.Analysismethodofwaterandwastewatermonitoring[S].Beijin:ChinaEnviromentPress,1989.213(inchinese).

[9] ZHANGRong_kun,LUOYing_hua.Studiesontheconstant_potentialchronoamperometryinthecaseoflami naflow[J].ChemicalJournalofchineseUniversities,1981,2(3):301(inchinese)