Abstract
The goals of this work were to demonstrate the ability of atomic force microscopy (AFM) to detect various immunological processes between antibodies and antigens.A sensor was designed by covalently linking the antibody of staphylococcal enterotoxin Cl (SEC1) on the self-assembled gold surface. This sensor permitted detection of antibody-antigen recognition events which were highly correlated with the topography under different conditions. The statistic data of AFM were analysed. As control experiments, nonspecific antigens and lower concentration SEC1 antigens were directly observed. In addition, an acidic solution was used to break the antigen-antibody pair and made the sensor reuse. Electrochemical evidence was provided to support the results obtained with AFM.
Keywords
AFM, Self-assembled, Electrochemical method, Specific ability, Dissociation
Publication Date
2002-11-28
Online Available Date
2002-11-28
Revised Date
2002-11-28
Received Date
2002-11-28
Recommended Citation
Sa-ying DONG, Hong-ren WANG.
Detection and Analysis of SEC1 Immunological Reaction by AFM and Electrochemical Method[J]. Journal of Electrochemistry,
2002
,
8(4): Article 11.
DOI: 10.61558/2993-074X.3305
Available at:
https://jelectrochem.xmu.edu.cn/journal/vol8/iss4/11
References
[1] ChiQ ,ZhangJ ,DongS ,etal.Directobservationofnativeandunfolddedglucoseoxidasestructuresbyscanningtunnelingmicroscopy[J].J .Chem.Soc.Faraday.Trans.,1994,90(14):2057.
[2] CullenDC ,LoweCR .AFMstudiesofproteinadsorption[J].JournalofColloidandInterfaceScience,1994,166:102.
[3] HinterdorferP ,BaumgartnerW ,GruberHJ ,etal.Detectionandlocalizationofindividualantibody_antigenrecognitioneventsbyatomicforcemicroscopyProc.Natl.Acad.SciUSA ,1996,93:3477.
[4] LeeKS ,KimTH ,ShinMC ,etal.Disposableliposomeimmunosensorfortheophyllinecombininganim munochromatographicmembraneandathick_filmelectrode[J].AnalyticaChimicaActa,1999,380:17.
[5] ChowdhuryPB ,LuckhamPF .ProbingrecognitionprocessbetweenanantibodyandanantigenusingatomicforcemicroscopyColloidsandSurfacesA[J].Physicochem.Eng.Aspects,1998,143:53.
[6] AllenS ,DaviesJ ,DaviesMC ,etal.Theinfluenceofepitopeavailabilityonatomic_forcemicroscopestudiesofantigen_antibodyinteractions[J].Biochem.J .,1999,341:173.
[7] WillemsenOH ,SnelMME ,VanderWerfKO ,etal.Stimultaneousheightandadhesionimagingofanti body_antigeninteractionsbyatomicforcemicroscopy[J].BiophysicalJournal,1998,75:2220.
[8] Browning_KelleyME ,Wadu_MesthrigeK ,HariV ,etal.Atomicforcemicroscopicstudyofspecificanti gen/antibodybinding[J].Langmuir,1997,13:343.
[9] PerrinA ,LanetV ,TheretzA .Quantificationofspecificimmunologicalreactionbyatomicforcemicroscopy[J].Langmuir,1997,13:2557.
[10] JonesVW ,KensethJR ,PorterMD .Microminiaturizedimmunoassaysusingatomicforcemicroscopyandcompositionallypatternedantigenarrays[J].Anal.Chem.,1998,70:1233.
[11] KingKD ,AndersonGP ,BullockKE ,etal.DetectingstaphylococcalenterotoxinBusinganautomatedfiberopticbiosensor[J].Biosensor&Bioelectronics,1999,14:163.
[12] YuH .Useofanimmunomagneticseparation_fluorescentimmunoassay(IMS_FIA)forrapidandhighthroughputanalysisofenvironmentalwatersamples[J].AnalyticaChimicaActa,1998,376:77.
[13] KientzCE ,HulstAG ,WilsERJ.DeterminationofstaphylococcalenterotoxinBbyon_line(micro)liquidchromatography_electrospraymassspectrometry[J].JournalofChromatographyA ,1997,757:51.
[14] DongSa_ying.StudyontheelectrochemistryandinsituFTIRreflectionspectroscopyofenzymeimmuno electrode(inChinese)[D].Tianjin:AppliedChemistryDepatrmentofTianjinUniversity,1994.
[15] LiuM ,RechnitzGA .Capcitiveimmunosensingofpolycyclicaromatichydrocarbonandproteinconjugates[J].AnalyticalLetters,1998,31(12):2025.
[16] BerggrenC ,JohanssonG .Capacitancemeasurementsofantibody_antigeninteractionsinaflowsystem[J].Anal.Chem.,1997,69:3651.