Abstract
The 3-factor and 3-level orthogonal experiment was designed and through the comparison of the different films' antibacterial properties measured by bacterial colony counting and the corrosion resistance studied with the AC impedance method. The optimal plating conditions of the (Ag)-Ni/Cr composite plating, a novel functional plating, were determined. The results have indicated that the (Ag)-Ni/Cr composite plating is characterized by both antibacterial and corrosion resisting properties and has its wide applied prospect.
Keywords
Orthogonal experiment, Bacterialcolony counting, The AC impdance, An-tibacterial
Publication Date
2003-02-28
Online Available Date
2003-02-28
Revised Date
2003-02-20
Received Date
2002-10-08
Recommended Citation
Ya-ping Zhao, Jin-hua Wang, Ren-he Yin, Jin Zheng, Le-shu Yu.
Development and Study of the (Ag)-Ni/Cr Composite Plating with Antibacterial Properties and Corrosion Resistance[J]. Journal of Electrochemistry,
2003
,
9(1): 71-75.