Abstract
In 0.2 mol/L NaOH, cystine can cause an sensitive incision at -0.5 V (vs.SCE) of cathodic branch of dE/dt-E curve or second order differential simple oscillogram. Based on the oscillographic charateristic, second order differential simple oscillographic voltammetry was applied to the determination of cystine in tablet. The linear range and the detection limit for determination of cystine were 2.5×10-6~3.5×10-5 mol/L and 1.0×10-6 mol/L, respectively. The relative standard deviation for 2.000×10-5 mol/L cystine was 1.8% (n=5).
Keywords
Oscillographic analysis, Second order differential simple oscillo graphic voltammetry, Cystine
Publication Date
2003-11-28
Online Available Date
2003-11-28
Revised Date
2003-05-04
Received Date
2002-10-12
Recommended Citation
Fu-Fang TAO, Jian-Bin ZHENG.
Determination of Cystine by Second Order Differential Simple Oscillographic Voltammetry[J]. Journal of Electrochemistry,
2003
,
9(4): 471-474.